OEM Wireless 500 Volt Analog Voltage Measurement SensorThe OEM 500 VAC/VDC Voltage Measurement Sensor is an analog measuring device that reports the measured voltage on user specified intervals. The sensor has three operating modes, in which you can obtain the voltage measurement in VACrms (root mean squared), the peak voltage, or the DC voltage. The modes can be set by the user; the default mode measures VACrms. All sensor data is securely transmitted through an OEM wireless gateway to the iMonnit Online Sensor Monitoring software where it is stored and viewable from any web enabled device. The iMonnit online software system is completely white label (private brand) capable, allowing you to offer the online monitoring service as your own. Email and SMS text messages can be configured through the online system to alert users immediately when a defined parameter has been met or exceeded. « Learn more about OEM online monitoring software Product Features:
* Actual range may vary depending on environment. |
|
OEM Wireless 500 Volt Sensor - Technical Specifications |
|
Documentation | |
OEM Wireless 500 Volt Analog Voltage Measurement Sensor Data Sheet | |
OEM RF Board Specifications | |
Available Operating Frequencies | 900 MHz (25 Channels) 868 MHz (5 Channels) 433 MHz (15 Channels) |
Device Transmission Range | 300 - 500 ft. Non-LOS |
Approximate Battery Life | 300,000 Transmissions (~ 2-5 Years Depending on Settings*) |
Supply Voltage | 2.0 - 3.6 VDC ** |
Current Consumption | 0.7 μA (sleep mode) 2 mA (radio idle/off mode) 2 mA (measurement mode) 25 mA (radio RX mode) 35 mA (radio TX mode) |
Operating Temperature Range | -40°C to +85°C ( -40°F to +185°F ) *** |
Performance | 0.7% BFSL Accuracy |
Certifications | 900 MHz product; FCC and IC Certified. Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-RFSC1) Complies with Industry Canada standards. (IC: 9794A-RFSC1) 868 and 433 MHz product; CE Certified. Complies with CISPR 22:2008-09 / EN 55022:2010 - Class B and ETSI EN 300 220-2 V2.4.1 (2012-05). |
OEM Wireless 500 Volt Measurement Sensor Specifications | |
Sensor Resolution | 11 bit (single ended) |
Conversion Time | 228 μs |
Full Scale Voltage | Up to 500 VAC/VDC |
* Battery life depends on sensor reporting frequency and other variables.
** Hardware can not withstand negative voltage. Please take care when connecting power.
*** At temperatures above 100°C, programmed memory can be lost.
*** If application exceeds 500 Volts the sensor will return a mzximum reading of 500 Volts.